Par0016 - elastix
Registration Description
intrapatient; Multi B-spline transformation; sliding motion
Image data
- 3D chest CT
- Lung
- 16 scans (10 dir-lab, 6 extended popi-model)
- Voxel size mostly 0.97x0.97x2.5 mm for dir-lab patients // 1x1x2 for extended popi-model.
- Dimension: on average about 256 x 256 x 100 for 5 first dir-lab patients // 512 x 512 x 128 for 5 last dir-lab patient // 512 x 512 x 165 for extended popi-model
Popi-model
Patient Download
dir-lab
my masks are available here
Application
Thoracic registration between End-Inhale // End-Exhale with sliding motion.
Registration Settings
For parameter files see the Elastix Model Zoo repository on GitHub.
elastix
version: svn (probably 4.6)
Command line calls:
elastix -f 50.mhd -m 00.mhd -p params.txt -labels mm_50.mhd -fMask patient_mask_50.mhd -out outDir
Published in
V. Delmon, S. Rit, R. Pinho, and D. Sarrut, "Direction dependent B-splines decomposition for the registration of sliding objects", Proceedings of the Fourth International Workshop on Pulmonary Image Analysis, Toronto, Canada, pp. 45–55, 09/2011.